描述:
LKM110 - transducer for connection head form B, programmable, PT100 Analogue transducer for PT100 For assembly in B head Output signal 4 → 20 mA Programmable with programming kit LKM111 available (option) **LKM110 transducer** | ---|--- Input: | PT100, 2 / 3-wire circuit Measuring current: | max. 0.7 mA Zero point: | -100 °C → +100 °C Range: | 20 °C → 950 °C Linearity fault: | Loop voltage: | 10 → 35 Vdc, resistant to reverse polarity Load: | max. 800 Ω @ 24 V Output: | 4 → 20 mA current loop Sensor break: | >20 mA Short circuit: | Reaction time: | Operating temperature: | -40 °C → +85 °C Terminal type: | Screw terminals Terminal range: | 0.13 → 1.5 mm2 Weight: | 30 g **LKM111 programming kit** | Configuration program: | CD-Rom (for WIN"95 to WIN"XP) Programming cable: | Connection to parallel interface LPT1 ### 认可 CE ### 标准 EN50081-1 (EMC emission), EN50082-2 (EMC interference immunity) ### Temperature Transducer
1368
-
描述:
LKM 211/213/214 — 变换器,用于 PT100 和热电偶 模拟温度变换器,用于 PT100 传感器和 J、K 型热电偶 外壳:EMG25,聚碳酸脂 传感器故障和短路检测 EMC 符合 EN50081-1 和 EN50082-2 **通用** | ---|--- 环路电压: | 10 → 36 V 直流 输出: | 4 → 20 mA,电流回路,抗反向极性 输出: | 0 → 10 V,短路保护 工作温度: | -40 °C → +85 °C 存储温度: | -40 °C → +120 °C **LKM 211,用于热电偶,4 → 20 mA** | 线性故障: | 故障参考接线: | ±0.5 °C 传感器故障 | >20 mA **LKM 213 用于 PT100,4 → 20 mA** | 2、3 或 4 导线电路 | 线性故障: | 校准故障: | ±0.1 °C 传感器故障 | >20 mA 传感器短路: | **LKM 214 用于 PT100,0 → 10 V** | 2、3 或 4 导线电路 | 电源电压: | 18 → 36 V 直流 功率消耗: | 约 30 mA 负载电阻: | >5 kΩ 线性故障: | 校准故障: | ±0.1 °C 传感器故障 | >10 V 传感器短路: | ### DIN 卡轨安装
7896
Scroll